NEW QUESTION 27
An engineer is checking a newly delivered Dell EMC PowerEdge R640 server that will be deployed for a new database environment The inventory consists of:

The server power configuration will be set for gnd redundancy The management switch is 1000 Base-T and the top of rack switches 10Gb What additional component(s) is needed for this configuration?

  • A. C20 to C21, PDU style, 250 V, 16 Amp, 3 5 meters power cord - qty 2
  • B. Hot-plug power supply, 750 W - qty 1
  • C. Dell Networking, cable, 40GbE (QSFP+) to 4 x 10GbE SFP+ passive copper breakout cable, 3 meters - qty 2
  • D. Hot-plug power supply, 1100W - qty 1

Answer: B

 

NEW QUESTION 28
What is a characteristic of SupportAssist Enterprise on Dell EMC PowerEdge 14G servers?

  • A. Dispatches technical support from Dell for all Dell servers, storage, and networking devices
  • B. Proactive, predictive, and automated support technology to enable faster resolution and reporting
  • C. Includes onsite monitoring and automated collection of system state information
  • D. Used for customers that want monitoring of fewer than 1,000 server, storage, and networking devices

Answer: B

 

NEW QUESTION 29
A technician is creating a virtual disk in the iDRAC (2x 4 TB NL-SAS in RAID 1) to install Windows 2016 They manually boot to the OS installation media without using the Lifecycle Controller OS Deployment wizard Only the first 2048 GB on the virtual disk can be partitioned How should the technician obtain access to the remaining 2 TB (approximately) of storage?

  • A. Upgrade to a newer version of the operating system
  • B. Delete the 4 TB virtual disk and create a virtual (boot) disk no larger than 2048 GB
  • C. Use the Lifecycle Controller OS Deployment Wizard to deploy the OS on this server
  • D. Use F2 to go into the BIOS, change the BIOS boot mode to UEFI, and try again

Answer: D

 

NEW QUESTION 30
For security reasons, the Dell EMC PowerEdge server power button must be disabled. Use the System Setup Utility in the simulator to disable the power button. When you have finished using the simulator, click Next.

Answer:

Explanation:
Send us your suggestion for this simulation task.

 

NEW QUESTION 31
What happened on April 30, 2019?


Note: It is necessary to dose (x) the simulator window before you can select a response to this question.

  • A. Option B
  • B. Option A
  • C. Option C
  • D. Option D

Answer: C

 

NEW QUESTION 32
Starting from which Dell EMC PowerEdge server hardware generation is the Micro SD card in the IDSDM/vFlash module supported?

  • A. 12G
  • B. 14G
  • C. 11G
  • D. 13G

Answer: B

 

NEW QUESTION 33
An engineer needs to upgrade a Dell EMC PowerEdge R440 server from a single PSU to dual PSU configuration. There are unused PSU modules from PowerEdge R430 and R420 servers available, and they have the same wattage ratings.
What should the engineer do to complete the task?

  • A. Configure the PowerEdge R440 PSU with 1+1 configuration
  • B. Add the PowerEdge R420 PSU modules to the PowerEdge R440
  • C. Order a new PSU specific to the existing PowerEdge R440
  • D. Add the PowerEdge R430 PSU modules to the PowerEdge R440

Answer: C

 

NEW QUESTION 34
Which card connects to the PCI bus, is physically smaller than a on the system board of a Dell EMC PowerEdge 14G server?

  • A. OCP
  • B. PCIe
  • C. FPGA
  • D. NDC

Answer: C

 

NEW QUESTION 35
Which rear disk drive option is available in a Dell EMC PowerEdge R740xd server?

  • A. 6x2 5" drives
  • B. 2x3.5" drives
  • C. 4x 3.5" drives
  • D. 8x2 5" drives

Answer: B

 

NEW QUESTION 36
Dell EMC PowerEdge 14G servers support which technology?

  • A. AMD GuardMI
  • B. Intel Boot Guard
  • C. iDRAC8
  • D. Quicksync 1.0

Answer: A

 

NEW QUESTION 37
A technician installs eight servers into a fully operational rack with top of rack switch Each server has a quad 1Gb NIC and redundant power supplies The company uses iDRAC in shared LOM mode with LOM1 as the selected NIC What should the technician do to verify iDRAC connectivity on each server?

  • A. iDRAC Datacenter license is installed.
  • B. Ethernet port LOM1 is cabled and the link light is green.
  • C. iDRAC Enterprise license is installed
  • D. iDRAC dedicated NIC port is cabled and the link light is green

Answer: B

 

NEW QUESTION 38
What is a valid password option available from the iDRAC9 Unique ID feature?

  • A. Secure Default
  • B. Randomly Generated
  • C. Encryption Default
  • D. Legacy Generated

Answer: B

 

NEW QUESTION 39
Match each RAID level to its characteristic.

Answer:

Explanation:

 

NEW QUESTION 40
Which processor configuration is used by the Dell EMC PowerEdge R740 server?

  • A. 4 socket AMD
  • B. 4 socket Intel
  • C. 2 socket Intel
  • D. 2 socket AMD

Answer: C

 

NEW QUESTION 41
A technician is sent on-site to troubleshoot a server that produced an error message during the most recent POST, but then completed the POST and booted to the operating system. The user cannot remember the specific error and no entry was made in the error log relating to this error.
How can the technician find out what the error message was?

  • A. Access the iDRAC and view the last boot cycle video capture entry
  • B. Export the Server profile and analyze for any POST errors
  • C. Access the Lifecycle Controller and view the last boot cycle video capture entry
  • D. Reload the BIOS firmware

Answer: A

 

NEW QUESTION 42
After completing a disk rebuild operation, a technician needs to configure the system so that the rebuild process happens faster the expense of slowing users down.
Which setting should be changed?

  • A. Rebuild Rate in the iDRAC GUI
  • B. System Profile to Performance in the BIOS settings
  • C. Rebuild Rate in the BIOS settings
  • D. System Profile to Performance in the iDRAC GUI

Answer: A

 

NEW QUESTION 43
An engineer needs to upgrade a Dell EMC PowerEdge R440 server from a single PSU to dual PSU configuration. There are unused PSU modules from PowerEdge R430 and R420 servers available, and they have the same wattage ratings.
What should the engineer do to complete the task?

  • A. Configure the PowerEdge R440 PSU with 1+1 configuration
  • B. Order a new PSU specific to the existing PowerEdge R440
  • C. Add the PowerEdge R430 PSU modules to the PowerEdge R440
  • D. Add the PowerEdge R420 PSU modules to the PowerEdge R440

Answer: D

 

NEW QUESTION 44
You must configure a BOSS card with 2 x 120GB drives for a Dell EMC PowerEdge server. What is the only supported mode?

  • A. RAID 1
  • B. RAID 5
  • C. Non-RAID Mirroring
  • D. RAID 0

Answer: A

 

NEW QUESTION 45
What are the default settings used when applying firmware and a configuration to a replaced part using the Lifecycle Controller?

  • A. Firmware Allow version upgrade only
    Configuration: Disabled
  • B. Firmware: Match firmware of replaced part
    Configuration Apply always
  • C. Firmware: Upgrade to latest available version
    Configuration Apply always
  • D. Firmware Disabled
    Configuration Apply only if firmware match

Answer: B

 

NEW QUESTION 46
What is the minimum number of components, beside the system board, required to POST?

  • A. 1 PSU, 1 DIMM, and 1 CPU only
  • B. 1 PSU and 1 CPU only
  • C. 1 PSU, 1 CPU, 1 DIMM, and PERC SAS controller
  • D. PSUs, CPUs, and DIMMs as configured in BIOS

Answer: A

 

NEW QUESTION 47
What is required to use the iSM Automatic System Recovery feature?

  • A. OS watchdog timer disabled
  • B. OS watchdog timer enabled
  • C. Server Administrator installed
  • D. Server Administrator not installed

Answer: A

 

NEW QUESTION 48
A Dell EMC PowerEdge server logs the following CPU Machine Check error CPU1 IERR What action might solve the problem?

  • A. Reseat the IDSDM
  • B. Remove flea power
  • C. Swap the PERC controller
  • D. Update the Intel driver

Answer: D

 

NEW QUESTION 49
What is a key distinction between 1DRAC8 and 1DRAC9?

  • A. iDRAC8 offers HTML5 based GUI
  • B. iDRAC9 default credentials are root/calvin orderable only
  • C. iDRAC8 default credentials are customer orderable
  • D. iDRAC9 offers HTML5 based GUI

Answer: A

 

NEW QUESTION 50
......

Updated EMC DES-4122 Dumps – PDF & Online Engine: https://testking.practicedump.com/DES-4122-exam-questions.html